Change-Over Inline Filter FLNDBH/HC60

The FLND series change-over inline filter is an excellent filtration product, with the advantages of high efficiency, reliability, durability and easy maintenance, suitable for a variety of occasions and needs, is an indispensable and important product in liquid handling and hydraulic systems.The filter product number is 1306387.

Change-Over Inline Filter FLNDBH/HC60
Dimensions

 

 product-566-660


Features

 

  1. High reliability: FLND series change-over inline filters use advanced technology and materials to have very high reliability and stability.

  2. High filtration efficiency: FLND series change-over inline filters can efficiently filter out impurities and contaminants in the system, protecting the normal operation of the system and equipment.

  3. Low maintenance costs: FLND series change-over inline filters have very low maintenance costs and are very simple to replace and clean, which reduces the cost of use.

  4. Wide range of applications: FLND series change-over inline filters can be used in a variety of hydraulic systems and liquid handling equipment with strong versatility.


Applications

 

 FLND Applications


About Element Removal

 

Do not turn off the hydraulic system.

Determine which side of the filter is running.

Pull the lever away from the filter and rotate the lever 90° – the other side of the filter is now running.

Open the exhaust screw.

Sizes 40 – 140:

Unscrew the filter bowl on the side where it is no longer running (collect the liquid in a suitable container and clean or dispose of it according to environmental regulations).

Size 160 – 400:

Open the drain plug on the side of the filter that is no longer running (collect the liquid in a suitable container and clean or dispose of it according to environmental regulations) and unscrew the filter bowl.

Remove the filter element from the filter element nozzle of the filter head (check the surface of the filter element for contamination residues and large particles; These may indicate that the component is corrupted).

Replace or clean filter elements - Only W/HC (wire mesh) and V (metal fiber) elements can be cleaned.

Clean the filter bowl and filter head; Special attention must be paid to the thread.

Check the filter, especially the sealing surface, for mechanical damage.

Check the o-ring - replace if necessary.