banner

Products

Home>Products> Hydraulic Filter Element > PALL Filter

UH319 Filter Moisture & Particulate Combo Filter: For Critical Fluid Condition Monitoring

The UH319 filter by Ayater is widely recognized for its robust performance in "Mission Critical" hydraulic systems. By maintaining an ISO cleanliness code of 16/14/11 or better, the UH319 filter prevents the "sandblasting" effect of micro-contaminants on valve spools, extending the MTBF (Mean Time Between Failure) of the entire system.

UH319 Filter Moisture & Particulate Combo Filter: For Critical Fluid Condition Monitoring

 

Patented Ultipleat (laid-over pleat) filter medium pack

Coreless, cageless element configuration

Pall Stress-Resistant Technology (SRT) Media

In-to-out filter element flow path

Flows to 600 L/min (160 US gpm)

Pressures to 420 bar (6100 psi)

Ports, 112 in. top and side manifold mount

'H' option housing shown

Performance

 

Pressure Drop Information

Housing pressure drop using fluid with 0.9 S.G.
Housing pressure drop is directly proportional to specific gravity.

Housing pressure drop using fluid with 0.9 S.G.

 

Element Pressure Drop

Multiply actual flow rate times factor in table below to determine pressure drop with fluid at 32 cSt (150 SUS), 0.9 S.G. Correct for other fluids by multiplying new viscosity in cSt/32 (SUS/150) x new S.G./0.9. Note: factors are per 1000 L/min and per 1 US gpm.

319 Series Filter Elements - bard/1000 L/min (psid/US gpm)

Length Code AZ AP AN AS AT
08 5.52 (0.302) 2.30 (0.126) 1.82 (0.100) 1.32 (0.072) 0.82 (0.045)
13 3.31 (0.182) 1.38 (0.076) 1.09 (0.060) 0.79 (0.043) 0.49 (0.027)
20 2.18 (0.120) 0.91 (0.050) 0.72 (0.040) 0.52 (0.029) 0.33 (0.018)
40 1.10 (0.060) 0.46 (0.025) 0.36 (0.020) 0.26 (0.014) 0.16 (0.009)

 

Sample ΔP calculation

UH319 Series 13 in. length housing with S24 (112 in.) side manifold mount ports using AN grade media. Operating conditions 300 L/min flow rate using a hydraulic fluid of 50 cSt and specific gravity (s.g.) 1.2.

Total Filter ΔP
= ΔP housing + ΔP element
= (0.30 x 1.2/0.9) bard (housing)
+ ((300 x 1.09/1000) x 50/32 x 1.2/0.9) bard (element)
= 0.40 (housing) + 0.68 bard (element)
= 1.08 bard (15.7 psid)

Ordering Information / Part Numbers

 

For new installations, select one complete part number from each section below

Section 1

Housing P/N:
UH 319 [Table 1] [Table 2] ++ [Table 3] Z G 9 X106

Seal Kit P/N:
UH 319 SKZ

Table 1: Housing Orientation Options

Code Port
C Cap service (tube up) -standard
H Head service (tube down)

Table 2: Housing Port Options

Code Port
K24 112 in. top mount manifold
S24 112 in. side mount manifold

Table 3: Housing Length Options

Code Length (in.)*
08 8
13 13
20 20
40 40
* Nominal length

 

Section 2

Element P/N:
UE 319 [Table 1] [Table 2] Z

Table 1: Filter Element Options

Code ßx(c) ≥1000
based on ISO 16889
CST Rating*
AZ 3 08/04/01
AP 5 12/07/02
AN 7 15/11/04
AS 12 16/13/04
AT 22 17/15/08
* CST: Cyclic Stabilization Test to determine filter rating under stress conditions, based on SAE ARP4205

Table 2: Filter Element Length Options

Code Length (in.)*
08 8
13 13
20 20
40 40
* Nominal length

 

Section 3

(At least one Differential Pressure Indicator or 'B' type blanking plug must be ordered)

Differential Pressure Indicator P/N:
RC [Table 1] 091 Z [Table 2] [Table 3] [Table 4]

Note: Two Differential Pressure Indicators can be fitted on this housing

Note: If no differential pressure indicator is selected, 'B' type blanking plug (P/N HC9000A104Z) must be ordered separately and fitted to replace the plastic shipping plug.
 

Table 1: Differential Pressure Indicator Options*

Code Indicator 'H' Dim.
778NZ 'P' type Visual indicator with thermal lockout 21mm (0.83 in.)
860MZ 'D' type Visual indicator with no thermal lockout 21mm (0.83 in.)
861CZ 'L' type Electrical switch (SPDT) with 6 in.leads 38mm (1.50 in.)
861CZ 'M' type Electrical switch (SPDT) with DIN43650 connector and matching cap 78mm (3.07 in.)
861CZ 'R' type Electrical switch (SPDT) and neon light indicator with DIN43650 connector and cap 89mm (3.50 in.)
771BZ 'S' type Electrical switch (SPDT) with 3-pin MS connector 57mm (2.24 in.)
* Other options available on application.

Table 2: Differential Pressure Indicator Material

Code Pressure Setting
Omit Aluminium Alloy Indicator: use at operating pressures < 200 bar (3000 psi)
SS Stainless Steel Indicator: use at operating pressures > 200 bar (3000 psi)
* Other setting options are available; contact Ayater.

Table 3: 'M' & 'R'-Type Indicator Codes*

Code Option
YM 'M' option
YR 'R' option
* Use only if 'R' or 'M' Indicator is selected from Table 1

Table 4: 'R' Indicator Options

Code Option
110AC 110V AC
220AC 220V AC
24DC 24V DC

 

 

Hot Tags: uh319 filter moisture & particulate combo filter: for critical fluid condition monitoring, China, manufacturers, suppliers, factory, customized, Pall Filter Cross Reference, Pall Filter Element HC8314FKZ16Z, Pall Filter Cartridges, Pall Filter Element HC8310FKS39Z, Pall Hydraulic Oil Filter HC9601FCT4Z, Pall Oil Filter