The UH319 filter by Ayater is widely recognized for its robust performance in "Mission Critical" hydraulic systems. By maintaining an ISO cleanliness code of 16/14/11 or better, the UH319 filter prevents the "sandblasting" effect of micro-contaminants on valve spools, extending the MTBF (Mean Time Between Failure) of the entire system.

Patented Ultipleat (laid-over pleat) filter medium pack
Coreless, cageless element configuration
Pall Stress-Resistant Technology (SRT) Media
In-to-out filter element flow path
Flows to 600 L/min (160 US gpm)
Pressures to 420 bar (6100 psi)
Ports, 11⁄2 in. top and side manifold mount

Housing pressure drop using fluid with 0.9 S.G.
Housing pressure drop is directly proportional to specific gravity.

Multiply actual flow rate times factor in table below to determine pressure drop with fluid at 32 cSt (150 SUS), 0.9 S.G. Correct for other fluids by multiplying new viscosity in cSt/32 (SUS/150) x new S.G./0.9. Note: factors are per 1000 L/min and per 1 US gpm.
| Length Code | AZ | AP | AN | AS | AT |
| 08 | 5.52 (0.302) | 2.30 (0.126) | 1.82 (0.100) | 1.32 (0.072) | 0.82 (0.045) |
| 13 | 3.31 (0.182) | 1.38 (0.076) | 1.09 (0.060) | 0.79 (0.043) | 0.49 (0.027) |
| 20 | 2.18 (0.120) | 0.91 (0.050) | 0.72 (0.040) | 0.52 (0.029) | 0.33 (0.018) |
| 40 | 1.10 (0.060) | 0.46 (0.025) | 0.36 (0.020) | 0.26 (0.014) | 0.16 (0.009) |
UH319 Series 13 in. length housing with S24 (11⁄2 in.) side manifold mount ports using AN grade media. Operating conditions 300 L/min flow rate using a hydraulic fluid of 50 cSt and specific gravity (s.g.) 1.2.
Total Filter ΔP
= ΔP housing + ΔP element
= (0.30 x 1.2/0.9) bard (housing)
+ ((300 x 1.09/1000) x 50/32 x 1.2/0.9) bard (element)
= 0.40 (housing) + 0.68 bard (element)
= 1.08 bard (15.7 psid)
For new installations, select one complete part number from each section below
| Code | Port |
| C | Cap service (tube up) -standard |
| H | Head service (tube down) |
| Code | Port |
| K24 | 11⁄2 in. top mount manifold |
| S24 | 11⁄2 in. side mount manifold |
| Code | Length (in.)* |
| 08 | 8 |
| 13 | 13 |
| 20 | 20 |
| 40 | 40 |
| Code | ßx(c) ≥1000 based on ISO 16889 |
CST Rating* |
| AZ | 3 | 08/04/01 |
| AP | 5 | 12/07/02 |
| AN | 7 | 15/11/04 |
| AS | 12 | 16/13/04 |
| AT | 22 | 17/15/08 |
| Code | Length (in.)* |
| 08 | 8 |
| 13 | 13 |
| 20 | 20 |
| 40 | 40 |
(At least one Differential Pressure Indicator or 'B' type blanking plug must be ordered)
Note: Two Differential Pressure Indicators can be fitted on this housing
Note: If no differential pressure indicator is selected, 'B' type blanking plug (P/N HC9000A104Z) must be ordered separately and fitted to replace the plastic shipping plug.
| Code | Indicator | 'H' Dim. |
| 778NZ | 'P' type Visual indicator with thermal lockout | 21mm (0.83 in.) |
| 860MZ | 'D' type Visual indicator with no thermal lockout | 21mm (0.83 in.) |
| 861CZ | 'L' type Electrical switch (SPDT) with 6 in.leads | 38mm (1.50 in.) |
| 861CZ | 'M' type Electrical switch (SPDT) with DIN43650 connector and matching cap | 78mm (3.07 in.) |
| 861CZ | 'R' type Electrical switch (SPDT) and neon light indicator with DIN43650 connector and cap | 89mm (3.50 in.) |
| 771BZ | 'S' type Electrical switch (SPDT) with 3-pin MS connector | 57mm (2.24 in.) |
| Code | Pressure Setting |
| Omit | Aluminium Alloy Indicator: use at operating pressures < 200 bar (3000 psi) |
| SS | Stainless Steel Indicator: use at operating pressures > 200 bar (3000 psi) |
| Code | Option |
| YM | 'M' option |
| YR | 'R' option |
| Code | Option |
| 110AC | 110V AC |
| 220AC | 220V AC |
| 24DC | 24V DC |
Hot Tags: uh319 filter moisture & particulate combo filter: for critical fluid condition monitoring, China, manufacturers, suppliers, factory, customized, Pall Filter Cross Reference, Pall Filter Element HC8314FKZ16Z, Pall Filter Cartridges, Pall Filter Element HC8310FKS39Z, Pall Hydraulic Oil Filter HC9601FCT4Z, Pall Oil Filter