banner

Products

Home>Products> Hydraulic Filter Element > HYDAC Filter

Ayater HFM Filter Size 95: Advanced Inline Fluid Contamination Control

Maximize hydraulic uptime with our size 95 HFM filter, featuring an auto-reset visual pop-up indicator. Delivering superior 10-micron filtration at up to 140 LPM, this robust unit features a built-in 7-bar bypass valve and a ductile iron head for extreme durability.

Ayater HFM Filter Size 95: Advanced Inline Fluid Contamination Control
72b98d988f51bda24e8be999a1771bc8.jpg

Elevating Uptime with Intelligent Monitoring

 

One of the most highly praised and standout features of this specific filtration assembly is the auto-reset pop-up indicator hydraulic filter design. As microscopic particulate matter inevitably accumulates deep within the fiberglass media during regular operation, the differential pressure across the element naturally begins to rise. Once this internal pressure differential reaches a critical pre-calibrated threshold, the highly visible pop-up indicator triggers, immediately alerting maintenance personnel that an element change is urgently required. Unlike older, frustrating manual-reset mechanisms that rely entirely on operator memory, this advanced indicator resets itself automatically upon system depressurization and the installation of a fresh element. This drastically reduces the possibility of human error and ensures continuous, highly accurate system monitoring.

Robust Size 95 Architecture

 

When dealing with heavy flow rates, surface area dictates efficiency. The Ayater size 95 mobile hydraulic filtration footprint provides an exceptionally large media surface area compared to standard compact units. This increased size allows the 10-micron fiberglass element to capture and hold significantly larger volumes of abrasive dirt, sludge, and oxidation byproducts before requiring a changeout. By maximizing the time interval between maintenance stops, fleet operators experience drastically reduced machinery downtime, directly improving overall project profitability and operational workflow.

67cc117bb6ccefd71abd46b99e70db9b.jpg
4457a6fcac92c3f08a93a593cb844c1c.jpg

Bypass Valve and Pressure Management

 

Fluid viscosity changes dramatically in relation to ambient temperature, especially in mobile machinery exposed to severe outdoor weather conditions. During freezing cold starts, thick hydraulic oil struggles to pass through fine filtration media, which can inadvertently starve downstream components of vital lubrication. To seamlessly combat this phenomenon, the unit acts as a highly reliable 101.5 psi bypass inline fluid purifier. The precisely calibrated 7-bar bypass valve opens momentarily during these high-viscosity fluid surges, allowing the oil to bypass the primary element. This guarantees continuous downstream flow and prevents the filter element from suffering devastating structural damage, seamlessly closing and resuming full filtration once the fluid warms up to its nominal operating temperature.

High Flow Capabilities for Modern Demands

 

With equipment cycle times becoming faster, hydraulic systems must move more fluid than ever. Designed for 140 LPM inline hydraulic pressure filter applications, the internal flow paths of the Ayater ductile iron head have been heavily optimized using advanced computational fluid dynamics. This ensures that even at maximum flow velocities, the pressure drop (Delta P) remains incredibly low, maximizing the mechanical efficiency of your hydraulic pumps.

HFM drawing (7).png

Technical Specification Grid

Feature Detailed Specification
System Classification Inline High-Pressure Hydraulic Filter Assembly
Max Pressure Tolerance 400 bar (5800 psi) continuous rating
Rated Flow Capacity Up to 140 L/min (37 GPM)
Filtration Rating 10µm Multi-pass Microglass
Bypass Valve Calibration 7 bar (101.5 psi)
Element Structural Limit 20 bar (290 psi) Collapse Pressure
Threaded Connection G 1 (Metric/BSPP standard)
Indicator Type Visual pop-up (Auto-reset feature)
Housing Construction Ductile Iron Head / Threaded Steel Bowl
Standard Elastomers Nitrile (NBR)
Operating Temp Range -10°C to +100°C (+14°F to +212°F)
9b4115b24ca47c40ce9d1d4fa5351858.jpg

Servicing and Handling Protocols
 

Properly maintaining the Ayater HFM filter ensures decades of reliable service. The top of the ductile iron head features standard mounting holes, allowing the unit to be rigidly secured to the machine chassis, preventing dangerous vibrations from loosening hydraulic fittings. When the visual indicator flags a blockage, technicians simply unscrew the bottom-mounted steel bowl. The old element is extracted downwards, bringing any settled debris with it. Always ensure the internal housing threads are wiped clean and the new element's O-ring is properly lubricated with clean hydraulic oil before reassembly to maintain the unit's 400 bar integrity.

about AYATER

 

AYATER (3).jpg

Core Positioning

Ayater is a professional manufacturer and solution provider of industrial hydraulic pressure filtration equipment, focusing on high-pressure hydraulic filter R&D, production and sales.Currently, the company has been recognized as a national specialized, innovative, small and medium-sized enterprise, a high-tech enterprise and an innovative enterprise.

AYATER (2).jpg

Market advantages

Currently, exports have reached over 70 countries. We have our own brand agents in 5 countries, and are also the manufacturers authorized by multiple international brands.

AYATER (1).jpg

Customized Services

Ayater offers one-stop hydraulic filtration services, including product selection, on-site debugging, maintenance guidance and customized development. We provide tailor-made solutions for special fluid compatibility and pressure demands, with a professional team supporting global customers efficiently.

Hot Tags: ayater hfm filter size 95: advanced inline fluid contamination control, China, manufacturers, suppliers, factory, customized, Hydac 0250DN010BN4HC V Replacement Filter, HYDAC Oil Filter 1300R050WHC, Hydac Filter Alternative, Hydac Cartridge Oil Filter 0660R010BN4AM, Hydac Filter Element 0100RN010BNHC, Hydac Hydraulic Filter Cartridge 0400DN025WHC